The Main characteristics
of Piezoelectric Ceramic Materials Produced by Kunshan Risun Electronic Co., Ltd. |
Parameters |
Symbols | Materials | |||||
PT-A | P-6C1 | P-51A | P-52A | P-53A | P-54A | ||
Electro mechanical coupling coefficient | kp | 0.10 | 0.46 | 0.60 | 0.62 | 0.62 | 0.62 |
k31 | 0.06 | 0.34 | 0.37 | 0.38 | 0.38 | 0.38 | |
k33 | 0.45 | 0.58 | 0.68 | 0.72 | 0.72 | 0.72 | |
kt | 0.45 | 0.40 | 0.45 | 0.48 | 0.48 | 0.48 | |
Relative dielectric constant | ¦ÅT33 / ¦Å0 | 350 | 1270 | 920 | 1900 | 2190 | 2530 |
Piezoelectric strain constant | d33¡Á10-12C/N | 75 | 300 | 280 | 400 | 420 | 450 |
d31¡Á10-12C/N | -6.5¡¡ | -120 | -130 | -200 |
-220 |
-230 | |
Mechanical quality factor | Qm | 2000 | 1200 | 110 | 90 | 90 | 90 |
Frequency constant | fr¡¤d kHz¡¤cm | 255 | 200 | 200 | 200 | 200 | 200 |
fr¡¤l kHz¡¤cm | 205 | 140 | 143 | 143 | 143 | 143 | |
fr¡¤t kHz¡¤cm | 260 | 205 | 210 | 210 | 205 | 205 | |
Temperature characteristic |
| TKfr |
(-20¡æ~80¡æ) ¡Á10-6 / ¡æ |
30 | 35 | 400 | ¡¡ | 400 | |
| TKCT |
(-20¡æ~80¡æ) ¡Á10-6 / ¡æ |
¡¡ | 50 | 2000 | ¡¡ | 2000 | ||
Curie temperature | Tc | 400 | 280 | 290 | 280 | 280 | 280 |
Dielectric loss | tg¦Ä£¨%£© | 1.0 | 0.3 | 1.5 | 1.6 | 1.6 | 1.6 |
Dielectric loss£¨400V/mm£© | tg¦Ä£¨400V/mm£¬%£© | ¡¡ | ¡¡ | ¡¡ | ¡¡ | ¡¡ | ¡¡ |
Features and usage | High frequency resonator | electro-acoustics, medical ultrasonic application | electro-acoustics, medical ultrasonic application | electro-acoustics, medical ultrasonic application | electro-acoustics, medical ultrasonic application | electro-acoustics, medical ultrasonic application |
¡¡ |
Parameters |
Symbols | Materials | |||||
P-5B4 | P-5C2 | P-42 | P-43 | P-82 | |||
Electro mechanical coupling coefficient | kp | 0.65 | 0.62 | 0.55 | 0.60 | 0.53 | |
k31 | 0.40 | 0.40 | 0.31 | 0.32 | 0.31 | ||
k33 | 0.76 | 0.75 | 0.63 | 0.65 | 0.63 | ||
kt | 0.54 | 0.50 | 0.46 | 0.50 | 0.47 | ||
Relative dielectric constant | ¦ÅT33 / ¦Å0 | 3910 | 4770 | 1240 | 1580 | 1180 | |
Piezoelectric strain constant | d33¡Á10-12C/N | 620 | 650 | 250 | 300 | 225 | |
d31¡Á10-12C/N | -300 | -350 | -120 | -150 | -100 | ||
Mechanical quality factor | Qm | 60 | 50 | 500 | 1000 | 800 | |
Frequency constant | fr¡¤d kHz¡¤cm | 200 | 190 | 225 | 215 | 230 | |
fr¡¤l kHz¡¤cm | 143 | 143 | 170 | 160 | 170 | ||
fr¡¤t kHz¡¤cm | 190 | 185 | 195 | 216 | 228 | ||
Temperature characteristic |
| TKfr |
(-20¡æ~80¡æ) ¡Á10-6 / ¡æ |
300 | ¡¡ | ¡¡ | ¡¡ | ¡¡ | |
| TKCT |
(-20¡æ~80¡æ) ¡Á10-6 / ¡æ |
2000 | 4000 | ¡¡ | 2500 | 2400 | ||
Curie temperature | Tc | 250 | 220 | 320 | 350 | 300 | |
Dielectric loss | tg¦Ä£¨%£© | 2.5 | 3.0 | 0.3 | 0.3 | 0.3 | |
Dielectric loss£¨400V/mm£© | tg¦Ä£¨400V/mm£¬%£© | ¡¡ | ¡¡ | 3.0 | 3.0 | 1.0 | |
Features and usage | electro-acoustics, medical ultrasonic application | electro-acoustics, medical ultrasonic application | high power transmissions, used for underwater sound transducer | High stability, high power transmissions | high power transmissions , used for ultrasonic cleaning and welding |